Go to main content

We are launching a new website! Learn more

Logo

Follow us

Envistar Flex – EcoCooler

Air handling unit with coil heat exchanger and cooling unit

Air handling unit with integrated controls and a wide range of functional sections. Integrated cooling unit with stepless cooling capacity.

Airflow

0.10–13.0 m3/s

18 sizes

High flexibility and large airflow range

IV Produkt Cloud

Can be controlled and monitored via cloud service

Cost-effective

Low installation and operating costs

mollier diagram

Air flow ranges for Envistar Flex

EcoDesign air flow

Technical max air flow

Coil heat exchanger double-stacked w/ cooling unitRotorRotor w/ cooling unitReversible heat pumpCounter-flow exchangerCounter-flow exchanger w/ cooling unitPlate heat exchangerCoil heat exchanger double-stackedCoil heat exchanger
1280
1080
980
850
740
600
480
400
360
300
240
190
150
100
m³/s
0.0
2.0
4.0
6.0
8.0
10.0
12.0

Filter within Envistar Flex

Technical dataforEnvistar Flex with coil recovery and EcoCooler

Here you will find dimensions and weights as well as power and performance information about Envistar Flex with coil recovery and EcoCooler .

SizeAir flow (m3/s)Dimension (mm)Control unit locationWeight (kg)Refrigerant amount (kg)Effect and fuse
MinSFPv1,6EcodesignMaxWidthHeightLengthWidth duct connectionHeight duct connectionR454B Circuit 1R454B Circuit 2R454B Circuit 3tonne CO2e (R454B) Circuit 1tonne CO2e (R454B) Circuit 2tonne CO2e (R454B) Circuit 3Cooling effect (kW)System voltage
100-2V
0.22
0.51
0.6
0.8
1020
1090
3320
700
300
On unit roof
790
1.8
-
-
0.84
-
-
15
400VAC
150-2V
0.33
0.92
1.15
1.5
1120
1470
3540
800
500
On unit roof
1050
2.9
-
-
1.35
-
-
23.7
400VAC
190-2V
0.42
1.18
1.58
2
1400
1470
3540
1000
500
On unit roof
1220
3.7
-
-
1.72
-
-
30.6
400VAC
240-2V
0.49
1.45
1.88
2.44
1400
1686
3760
1000
600
On unit end
1340
4.1
-
-
1.91
-
-
32.1
400VAC
300-2V
0.57
1.84
2.2
2.87
1616
1686
3760
1200
600
On unit end
1490
5.1
-
-
2.38
-
-
16.7
400VAC
360-1V
0.74
2.3
2.89
3.71
1616
2060
4320
1200
800
On unit end
1850
6
-
-
2.8
-
-
51.1
400VAC
360-2V
0.74
2.3
2.89
3.71
1616
2060
4320
1200
800
On unit end
1850
6
-
-
2.8
-
-
55.1
400VAC
400-1V
0.8
2.5
3.05
4
1880
1900
4060
1400
700
On unit end
1760
7
-
-
3.26
-
-
52.3
400VAC
400-2V
0.8
2.5
3.05
4
1880
1900
4060
1400
700
On unit end
1790
7
-
-
3.26
-
-
59.1
400VAC
480-0V
0.93
3
3.7
4.66
1990
2060
4160
1400
800
On unit end
2130
8.1
-
-
3.77
-
-
54.9
400VAC
480-1V
0.93
3
3.7
4.66
1990
2060
4160
1400
800
On unit end
2150
8.7
-
-
4.05
-
-
62.7
400VAC
480-2V
0.93
3
3.7
4.66
1990
2060
4160
1400
800
On unit end
2160
8.7
-
-
4.05
-
-
75.7
400VAC
600-1V
1.16
3.79
4.6
5.78
2200
2270
4160
1600
800
On unit end
2430
8.2
-
-
3.82
-
-
63.1
400VAC
600-2V
1.16
3.79
4.6
5.78
2200
2270
4160
1600
800
On unit end
2450
8.2
-
-
3.82
-
-
76.7
400VAC
600-3V
1.16
3.79
4.6
5.78
2200
2270
4160
1600
800
On unit end
2520
6.2
3.6
-
2.89
1.68
-
90.5
400VAC
740-2V
1.42
5.2
6.3
7.08
2480
2480
4480
2000
900
In unit next to fan
3100
10.1
-
-
4.71
-
-
81.9
400VAC
740-3V
1.42
5.2
6.3
7.08
2480
2480
4480
2000
900
In unit next to fan
3200
9.3
4.1
-
4.33
1.91
-
111.6
400VAC
850-1V
1.61
6.15
7.4
8.06
2560
2740
4480
2200
1000
In unit next to fan
3420
11.5
-
-
5.36
-
-
85.5
400VAC
850-2V
1.61
6.15
7.4
8.06
2560
2740
4480
2200
1000
In unit next to fan
3490
9.3
5.8
-
4.33
2.7
-
101.7
400VAC
850-3V
1.61
6.15
7.4
8.06
2560
2740
4480
2200
1000
In unit next to fan
3510
9.3
5.8
-
4.33
2.7
-
127.3
400VAC
980-1V
1.95
7.3
8.65
9.77
2890
3085
4480
2400
1100
In unit next to fan
3890
14.6
-
-
6.8
-
-
89.9
400VAC
980-2V
1.95
7.3
8.65
9.77
2890
3085
4480
2400
1100
In unit next to fan
4020
10.4
7.4
-
4.85
3.45
-
139.7
400VAC
1080-1V
2.02
7.8
9.5
10.14
3000
3195
4930
2400
1100
In unit next to fan
5130
11.3
7.1
-
5.27
3.31
-
108
400VAC
1080-2V
2.02
7.8
9.5
10.14
3000
3195
4930
2400
1100
In unit next to fan
5150
11.3
7.1
-
5.27
3.31
-
131.7
400VAC
1080-3V
2.02
7.8
9.5
10.14
3000
3195
4930
2400
1100
In unit next to fan
5240
7.1
5.8
5.8
3.31
2.7
2.7
158.6
400VAC
1280-1V
2.28
8.8
10.9
11.46
3180
3375
4930
2600
1200
In unit next to fan
5530
12.9
9
-
6.01
4.19
-
119.7
400VAC
1280-2V
2.28
8.8
10.9
11.46
3180
3375
4930
2600
1200
In unit next to fan
5630
12.9
9
-
6.01
4.19
-
145.9
400VAC
1280-3V
2.28
8.8
10.9
11.46
3180
3375
4930
2600
1200
In unit next to fan
5670
9.5
6.7
6.7
4.43
3.12
3.12
185.8
400VAC

Technical data for related products

Documentation forEnvistar Flex Coil Heat Exchanger EcoCooler

Here you will find general documentation for this product series. Download the latest versions of product brochures, instruction manuals, certificates, and other documents.

Your air handling unit

If you are looking for information about your AHU, search using the order number.

Document

Document type

Language

Version

Download/Share

Loading…

Control equipment with proprietary software

The entire range has integrated control equipment with software developed by us. We use Siemens Climatix hardware. The control equipment offers over 100 standard features to choose from so that you can optimise according to your needs. Air flow rates and temperatures can be optimised easily. The units can be connected to the web, IV Produkt Cloud or a parent system (BMS) via multiple communication protocols.

Project-specific electrical and control diagrams are included in the delivery. The unit has been function-tested and is ready for commissioning.

Ongoing projects?

Together, let's find the optimal solution for you!